Kurir Toko
Kurir kami akan mengirimkan ke alamat yang ditentukan
2-3 Hari
Kurir kami akan mengirimkan ke alamat yang ditentukan
2-3 Hari
Pembayaran:
Spesifikasi Produk :
Main |
---|
Range EasyLogic |
Product name EasyLogic PM2200 |
Product or component type Power meter |
Device short name PM2220 |
Complementary |
Device application Power monitoring Sub billing |
Power quality analysis Total harmonic distortion up to the 15th harmonic |
Type of measurement Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total |
Metering type Active, reactive, apparent energy (signed, four quadrant) Current I, I1, I2, I3 Peak demand currents Peak demand power PM, QM, SM Unbalance current Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Voltage U, U21, U32, U13, V, V1, V2, V3 Apparent power S, S1, S2, S3 Calculated neutral current |
Accuracy class Class 1 active energy conforming to IEC 62053-21 Class 1 reactive energy conforming to IEC 62053-24 Class 5 harmonic distorsion (I THD & U THD) |
Measurement accuracy Apparent power +/- 1 % Active energy +/- 1 % Reactive energy +/- 1 % Active power +/- 1 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 % |
Measurement current 5…6000 mA |
Measurement voltage 35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT |
Frequency measurement range 45…65 Hz |
[Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 % 44...277 V DC +/- 10 % |
Network frequency 50 Hz 60 Hz |
Ride-through time 100 ms 120 V AC typical 400 ms 230 V AC typical 50 ms 125 V DC typical |
[In] rated current 1 A 5 A |
Maximum power consumption in VA 6 VA at 277 V AC |
Maximum power consumption in W 3.3 W (power lines (AC)) 2 W at 277 V (power lines (DC)) |
Input impedance Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm) |
Tamperproof of settings Protected by access code |
Display type Backlit LCD |
Display colour Monochrome |
Display resolution 128 x 128 pixels |
Demand intervals Configurable from 1 to 60 min |
Information displayed Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % Harmonic amplitude |
Control type 4 x button |
Local signalling Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication |
Number of inputs 0 |
Number of outputs 0 |
Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V |
Communication port support Screw terminal block: RS485 |
Data recording Time stamping Min/max for 8 parameters |
Function available Real time clock |
Sampling rate 64 samples/cycle |
Cybersecurity Enable/disable communication ports |
Communication service Remote monitoring |
User language Spanish French English Russian Portuguese German Chinese |
Product certifications CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick |
Mounting mode Clip-on |
Mounting position Vertical |
Mounting support Framework |
Provided equipment 1 x installation guide |
Measurement category Category III 480 V Category II 480…600 V |
Electrical insulation class Double insulation Class II |
Flame retardance V-0 conforming to UL 94 |
Connections - terminals Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4 |
Material Polycarbonate |
Width 96 mm |
Depth Total : 76.09 mm Embedded : 61.64 mm |
Height 96 mm |
Product weight 300 g |
Compatibility code PM2220 |
Environment |
Service life 7 year(s) |
IP degree of protection IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
Relative humidity 5…95 % at 50 °C |
Pollution degree 2 |
Ambient air temperature for operation -10…60 °C |
Ambient air temperature for storage -25…70 °C |
Operating altitude <= 2000 m |
Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A |
Overvoltage category III |
Packing Units |
Unit Type of Package 1 PCE |
Number of Units in Package 1 1 |
Package 1 Height 11.800 cm |
Package 1 Width 8.800 cm |
Package 1 Length 12.000 cm |
Package 1 Weight 356.000 g |
Unit Type of Package 2 S03 |
Number of Units in Package 2 18 |
Package 2 Height 30.000 cm |
Package 2 Width 30.000 cm |
Package 2 Length 40.000 cm |
Package 2 Weight 7.012 kg |
Unit Type of Package 3 P06 |
Number of Units in Package 3 144 |
Package 3 Height 75.000 cm |
Package 3 Width 60.000 cm |
Package 3 Length 80.000 cm |
Package 3 Weight 78.000 kg |
Show More