• Aplikasi untuk instalasi listrik dengan kapasitas pemutusan rendah.
• Kapasitas Pemutusan : 7.5 kA s/d 30 kA pada 380/415 VAC.
• Thermal magnetic trip unit, tidak dapat disetel (non adjustable).
• Fixed type, front connection.
• Satu ukuran (frame size) untuk semua rating.
• Memenuhi standar IEC 60947-2.
• Rated @ 125V DC (1P) dan @ 250V DC (2P in series).
Spesifikasi Produk :
| Main |
|---|
| Range of product EasyPact |
| Product or component type Circuit breaker |
| Device short name Easypact EZC100B |
| Circuit breaker name Easypact EZC100B |
| Device application Distribution |
| Poles description 3P |
| Protected poles description 3t |
| Network type DC / AC |
| Network frequency 50/60 Hz |
| [In] rated current 15 A at 40 °C |
| [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 |
| [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity code B |
| Breaking capacity 10 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity 2.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 0.625 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 |
| Suitability for isolation Yes conforming to IEC 60947-2 |
| Utilisation category Category A |
| Trip unit name TM-D |
| Trip unit technology Thermal-magnetic |
| Trip unit rating 15 A at 50 °C |
| Protection type Overload protection Short-circuit protection |
| Pollution degree 3 conforming to IEC 60664-1 / IEC 947-1 |
| Complementary |
| Control type Toggle |
| Mounting mode Fixed |
| Mounting support Backplate |
| Upside connection Front |
| Downside connection Front |
| Mechanical durability 13,000 cycles |
| Connection pitch 25 mm |
| Local signalling Positive contact indication |
| Neutral protection setting Without protection |
| Earth-leakage protection Without |
| Height 130 mm |
| Width 75 mm |
| Depth 60 mm |
| Environment |
| Standards EN/IEC 60947-2 JIS C8201-2-2 EN/IEC 60947-1 GB/T 14048.2 |
| IP degree of protection IP20 conforming to IEC 60529 |
| IK degree of protection IK07 conforming to IEC 62262 |
| Ambient air temperature for operation -25…70 °C |
| Ambient air temperature for storage -35…85 °C |
| Packing Units |
| Package 1 PCE – Qty 1 14.0 × 8.0 × 10.0 cm 797 g |
| Package 2 S02 – Qty 12 40.0 × 30.0 × 15.0 cm 9.96 kg |
| Package 3 P06 – Qty 192 80.0 × 60.0 × 75.0 cm 167.092 kg |
| Contractual Warranty |
| Warranty 12 months |